Elevator part Elevator photocell Infrared Elevator led curtain Light Lift Door Detector light curtain
Basic Info
Model No.: SN-GM2-Z/09192P
Product Description
1.National paten
Elevator OTIS part Elevator photocell Infrared Elevator led curtain Light Lift Door Detector light curtain Description Sunny elevator light curtain includes two series---H series and P series. H series obtained national invention patent (No.ZL01105213.9) on Jan 26, 2005, it is widely used in luxury elevator and famous for its 8-channel special design, which means anyone can make uegent repair by pushing the elevator users when some diode is broken. P series can automatically increase the No.of infrared beam as the distance increases. Elevator Door Parts It can also remove the broken diode and keep the elevator working. This series is widely used in common elevator. door open detector P series light curtain is a standand type, it has the same quality and specification as the H series, otis spare parts but no channel switch design. P series has two main features. First, fixed beam with model 384Pand 192P, flexible beam with model 640PG and 320PG. The operation principle of flexible beams. When above 300mm, the number of infrared beam will increase to 320 in order to reduce the blind zone caused by long distance. The second feature is failure diode tolerance. The receiver is composed of four single circuit boards, there are two LED in the top board. One is used for power indication which is always lighting in normal condition. The other only lights up when one or several diodes fail to work. otis lift sizes It means the lights curtain is working is working under sickness. In three minutes, the broken diode will be removed automatically from funtion, and the elevator recovers. Techinical Specifications
Model | 9mm/16mm/35mm/2 in1 /Side-open/Safety edge |
Detecting distance | 0mm-5000mm |
Upper light beam | 1800±50mm |
Lower light beam | 17±5mm |
Light beam QTY | 156/192 beams (Optional) |
Photoelectric unit distance | 65mm |
Scan speed | 45 milliseconds; 22times/second |
Vertical tolerance | ≤±20mm |
Angle tolerance | ≤±7° |
Horizontal tolerance | ≤±10mm |
Response time | ≤80 milliseconds (relay output) |
Max.failure diodes | ≤3 points (optional) |
Alarming delay | 25s±5s |
Light negative | ≤100000Lux (sunlight) |
Power voltage | 85-264V AC; 60/50Hz |
Rating power consumption | ≤3.5VA |
Relay output | 120V AC 1A; 24V DC 1A |
Anti electricity level | 1500V AC; 1 Min |
Adaptive temperature | -25°C~+65°C |
EMC | GB/T17626,EN61000,retention memory A level |
Vibration | 5Hz~55Hz, amplitude 0.19mm,20 Min |
IP standard | IP63(light curtain) ; IP65( controller) |
Cable type & strength | Three core cable, strength resistance≤12N, 1 million times tortion,4.5m±10% |
Product Categories : Elevator Electrical Component > Elevator Photocell & Light Curtain & Curtain Light